                            {"id":4282,"date":"2019-01-19T23:28:32","date_gmt":"2019-01-19T22:28:32","guid":{"rendered":"https:\/\/www.radim.com\/personal-lab\/"},"modified":"2021-10-06T11:53:28","modified_gmt":"2021-10-06T09:53:28","slug":"personal-lab","status":"publish","type":"page","link":"https:\/\/www.radim.com\/en\/personal-lab\/","title":{"rendered":"Personal LAB"},"content":{"rendered":"<div id=\"headImg\" class=\"bw100\"><\/div>\n\n<div class=\"fullText radimH\"><h2 class=\"pageHead textLeft\">Personal LAB<\/h2><\/div>\n<div class=\"fullText radimSubHead pullUpSub\"><h3 class=\"pageHead textLeft\">The economic space miracle for small and medium-sized laboratories<\/h3><\/div>\n\n<article class=\"fullText dphclss0\">\n<ul>\n<li>Compact tabletop (95 x 85 x 70 cm)<\/li>\n<li>Capacity of 2 microtiter plates ESLISA)<\/li>\n<li>Double pipettes technique (tips and needle)<\/li>\n<li>Pipetting movements via samples and reagents<\/li>\n<li>Precise determination of up to 172 results for Total-IgE and spez. IgE in one test run<\/li>\n<li>Flexible user interface<\/li>\n<li>Control via external Windows PC<\/li>\n<\/ul>\n<\/article>\n<section class=\"pageSec sw100 \">\n<div class=\"twoThirdSpalten dphclss0\">\nWith the Personal LAB, you get fast and accurate results for Total-IgE and specific-lgE in one test run. Because the compact fully automatic machine fits into the smallest space and does not burden your budget with unnecessary laboratory technology, this is ideal for small and medium-sized laboratories.\nWith the Personal LAB the diagnoses of an allergy in a patient can be confirmed or excluded quickly, accurately and cost-effectively. With 172 total and specific-lgE determinations per test run and individual patient printouts, a highly efficient device system is available.\nThe most essential of allergy treatment is a quick and accurate diagnosis. This diagnosis also includes total-lgE and specific-lgE determination as well as ECP. However, the laboratory technology required for this is usually a lot of space and a lot of investment.\nThe Personal LAB delivers uncompromising maximum performance in a confined space without unnecessarily burdening your budget.\n<\/div>\n<div class=\"thirdSpalten dphclss0\">\n<div class=\"dphclss1 fullText\"><\/div>\nThe Personal LAB is a compact tabletop device.\n<\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Reagents<\/h3><\/div>\n<section class=\"pageSec sw100 \">\n<div class=\"twoThirdSpalten dphclss0\">\nIn the Personal LAB, all bottles (reagents &#8211; standards &#8211; controls) fit in dedicated and multifunctional racks. Different reagent-\/standard-racks can be loaded on the machine. Reagent bottles up to 60 ml can be used. The rack system is designed to combine more than one test per reagent cup to ensure maximum flexibility in your daily testing routine. The loading area is easily accessible for easy and simple loading of reagents, samples and polymer tips. Reagent and sample racks are easily removable for quick storage in the refrigerator.\n<\/div>\n<div class=\"thirdSpalten dphclss0\">\n<div class=\"dphclss2 fullText\"><\/div>\nMultiple reagents can be loaded in standard matching bottles.\n<\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Samples<\/h3><\/div>\n<section class=\"pageSec sw100 \">\n<div class=\"twoThirdSpalten dphclss0\">\nThe sample identification allows true positive sample identification of samples (PSID) via an integrated barcode reader. This new feature in combination with the new sample strip loader results in the most reliable sampling, sample identification and consistency test results. The new PSID functionality makes your Personal LAB even more complete and maintains its leading position for mid-sized automated micro-ELISA instruments.<br>\n<br>\n<strong>Sample tubes with the following dimensions are compatible with the Personal LAB:<\/strong>\n<ul>\n<li>Height: 55 to 75 mm.<\/li>\n<li>Diameter: 12 to 13.5 mm.<\/li>\n<\/ul>\n<\/div>\n<div class=\"thirdSpalten dphclss0\">\n<div class=\"dphclss3 fullText\"><\/div>\nSample identification (PSID) via integrated barcode reader\n<\/div>\n<\/section>\n\n<article class=\"fullText dphclss0\">\n<div class=\"dphclss4 fullText radimPicMobFix\"><\/div>\nSupervision of Workplace Personal LAB\n<\/article>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Dosing and diluting<\/h3><\/div>\n<section class=\"pageSec sw100 \">\n<div class=\"twoThirdSpalten dphclss0\">\nThe Personal LAB has a robotic arm operated by stepper motors and controlled by optical and mechanical sensors. It is equipped with 2 dosing systems, which allow to work independently and to allow a highly efficient pipetting. The two independent arms can use polymer tips of 1000 \u00b5l to dispense reagents in multi-dispensing mode and 200-\u00b5l-tips to deliver samples, standards and controls.<br>\nThe device is equipped with a pneumatic level sensor -PLS- (patented) for the polymer tip. The polymer tip system is equipped with a clot detection system. If the amount of fluid is insufficient, the device warns the operator both acoustically and visually. The Personal LAB performs automatic pre-dilution of samples, standards and controls. Up to 192 pre-dilutions can be carried out per run.\n<\/div>\n<div class=\"thirdSpalten dphclss0\">\n<div class=\"dphclss5 fullText\"><\/div>\nEasily accessible liquid containers are easy to handle.\n<\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Incubate and mixing<\/h3><\/div>\n<article class=\"fullText dphclss0\">\nThe plate case is designed for the simultaneous processing of two microtiter plates. Each microtiter plate can be programmed and edited completely individually. In addition, a single microtiter plate can be run.<br>\nThe plate holders can perform linear shaking with a programmable intensity and period. During incubation, the plates are placed in two independent chambers, which are thermally insulated at the temperature programmed by the operator.\n<\/article>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Washing<\/h3><\/div>\n<section class=\"pageSec sw100 \">\n<div class=\"twoThirdSpalten dphclss0\">\nThe washing station has an 8-channel wash head with two parallel needles each, suitable for washing both &#8216;U&#8217; and flat bottom wells. Cycles, volume and number of washes can be easily programmed by the operator and three wash buffers can be loaded on board at the same time.<br>\n<br>\n<strong>Washing volume:<\/strong> programmable from 100 to 2000 ml<br>\n<strong>Number of cycles:<\/strong> programmable from 1 to 9 cycles<br>\n<strong>Soaking time:<\/strong> programmable from 1 second to 3 minutes<br>\n<strong>Pressure:<\/strong> programmable<br><br>\n<article class=\"fullText\">Each protocol can be programmed by the operator with multiple washes that differ in cycle, volume, holding time, and pressure.<\/article>\n<\/div>\n<div class=\"thirdSpalten dphclss0\">\n<div class=\"dphclss6 fullText\"><\/div>\nWashing station Personal LAB\n<br>\n<\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Reading<\/h3><\/div>\n<article class=\"fullText dphclss0\">\nThe reading station has a photometer that can be programmed by the operator to read with a single, double or triple beam (vertical measurement). With a triple beam (over-range measurement), the instrument automatically converts the absorbance values measured at the different wavelengths.<br><br>\n\n<strong>The normally provided filters:<\/strong> 405, 450, 492, 550 and 620 nm<br>\n<strong>Optional filters:<\/strong> Other in the range 400-700 nm, up to 8 filters\n<\/article>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Simple device maintenance<\/h3><\/div>\n<article class=\"fullText dphclss0\">\nThe Perosnal LAB has minimal downtime to maximize the efficiency of your lab:<br>\nPreparation and follow-up of working hours: 5 minutes per day \/ no warm-up phase required<br>\nSelf-diagnostic and alarm procedures are an essential part of Perosnal LAB.<br><br>\n\nMaintenance procedures:<br>\n<br>\n<section class=\"pageSec sw100 dphclss7\">\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">daily<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">Cleaning at the end of the run &#8211; fully automatic.<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">weekly<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">General cleaning of the workspace of liquids.<br>\nEmpty all tanks to remove residual buffers. Rinse with DI water.<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">monthly<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">Wipe the workspace, baskets and waste bin.<br>\nCheck tanks and visible hoses<\/div><\/div>\n<\/section>\n<\/article>\n\n<section class=\"pageSec sw100 dphclss7\">\n<div class=\"dphclss8 fullText bw100 radimPicMobFix\"><\/div>\n<\/section>\n\n<div class=\"fullText radimH\"><h2 class=\"pageHead textLeft\">Technical specifications Personal LAB<\/h2><\/div>\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Dosing<\/h3><\/div>\n<section class=\"pageSec sw100 dphclss7\">\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">microtiter plates:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">2<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Parameter:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">max. 6 in one run<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Samples:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">max. 192 in one run<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Pipetting volume:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">10 \u00b5L &#8211; 1000 \u00b5L<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Precision tip 200 \u00b5l:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">Less than 2 % at 100 \u00b5l<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Tipp 1000 \u00b5L:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">Less than 2,5 % at 100 \u00b5l<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Throughput samples:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">88 in less than 15 min.<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Throughput reagents:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">96 Wells in less than 3 min.<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Fill level sensor:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">Pneumatic for polymertips<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Incubators:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">2<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Temperature:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">RT \/ RT +5 \u00b0C up to +45 \u00b0C<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Heating time:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">15 min<\/div><\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Washing<\/h3><\/div>\n<section class=\"pageSec sw100 dphclss7\">\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Buffer:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">2 with filler stander recognition<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Stations:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">1<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Liquid trap:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">3 ltr. with &#8220;Full&#8221; sensor<\/div><\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Photometer<\/h3><\/div>\n<section class=\"pageSec sw100 dphclss7\">\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Units:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">1<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Reading:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">from 0-3 OD (mono\/dual\/triple wavelength)<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Spectral range:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">400 &#8211; 700 nm<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Interference filters:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">5<\/div><\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Software<\/h3><\/div>\n<section class=\"pageSec sw100 dphclss7\">\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Operating system:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">Windows 10<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Interface:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">BiDirectional ASTM (LIS compatible)<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Internal quality control:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">Levey Jennings and Westguard rules<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Data reduction:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">Standard interpolations<\/div><\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Dimensions<\/h3><\/div>\n<section class=\"pageSec sw100 dphclss7\">\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Width:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">76 cm<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Depth:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">76 cm<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Height:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">69 cm<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Weight:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">75 kg<\/div><\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Electrical specifications<\/h3><\/div>\n<section class=\"pageSec sw100 dphclss7\">\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Voltage:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">110 or 220 V AC<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Frequency:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">50-60 Hz<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Power:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">450 VA<\/div><\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Compliance<\/h3><\/div>\n<article class=\"fullText dphclss0\">\nSafety CE certified\n<\/article>","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":3,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-4282","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.radim.com\/en\/wp-json\/wp\/v2\/pages\/4282","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.radim.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.radim.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.radim.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.radim.com\/en\/wp-json\/wp\/v2\/comments?post=4282"}],"version-history":[{"count":27,"href":"https:\/\/www.radim.com\/en\/wp-json\/wp\/v2\/pages\/4282\/revisions"}],"predecessor-version":[{"id":9490,"href":"https:\/\/www.radim.com\/en\/wp-json\/wp\/v2\/pages\/4282\/revisions\/9490"}],"wp:attachment":[{"href":"https:\/\/www.radim.com\/en\/wp-json\/wp\/v2\/media?parent=4282"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}