                            {"id":4289,"date":"2019-01-20T16:43:00","date_gmt":"2019-01-20T15:43:00","guid":{"rendered":"https:\/\/www.radim.com\/alisei-q-s\/"},"modified":"2020-10-09T10:50:22","modified_gmt":"2020-10-09T08:50:22","slug":"alisei-q-s","status":"publish","type":"page","link":"https:\/\/www.radim.com\/en\/alisei-q-s\/","title":{"rendered":"Alisei Q.S."},"content":{"rendered":"<div id=\"headImg\" class=\"bw100\"><\/div>\n\n<div class=\"fullText radimH\"><h2 class=\"pageHead textLeft\">Alisei Q.S.<\/h2><\/div>\n<div class=\"fullText radimSubHead pullUpSub\"><h3 class=\"pageHead textLeft\">Fully automatic microtiter plates ELISA Analyzer<\/h3><\/div>\n<article class=\"fullText dphclss0\">\n<ul>\n<li>Capacity of 6 microtiter plates (ELISA)<\/li>\n<li>Walk-Away-System<\/li>\n<li>Ideal for various ELISA applications of laboratory diagnostics:<br>Determination of hormones, tumor markers, infectious diseases &#8230;<\/li>\n<li>Up to 12 different assays at same time<\/li>\n<li>Standard curve recall and recalibration<\/li>\n<li>Time management system<\/li>\n<li>Quality control functions<\/li>\n<li>Monitoring the entire test run<\/li>\n<li>No disposable tips<\/li>\n<li>Flexible user interface<\/li>\n<\/ul>\n<\/article>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Solution for processing ELISA kits<\/h3><\/div>\n<article class=\"fullText dphclss0\">RADIM Germany, in collaboration with an Italian manufacturer of diagnostic instruments, offers you a solution for the automated application of ELISA assays &#8211; the automated ELISA instrument Alisei Q.S.. <strong>Our kits are for use on Alisei Q.S. designed and the test protocols are preinstalled.<\/strong><\/article>\n<section class=\"pageSec sw100 \">\n<div class=\"halfSpalten dphclss0\">\n<div class=\"dphclss1 fullText\"><\/div>\nSimple &#8216;loading&#8217; with reagent and sample racks, which can be stored in the refrigerator.\n<\/div>\n<div class=\"halfSpalten dphclss0\">\n<div class=\"dphclss2 fullText\"><\/div>\n6 microtiter plates (ELISA) are incubated, shaken and washed independently of each other\n<\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Reagents and samples<\/h3><\/div>\n<article class=\"fullText dphclss0\">\n<ul>\n<li>Removable rotating racks for reagents and sample tubes<\/li>\n<li>Maximum capacity: 240 sample tubes<\/li>\n<li>Simultaneous loading of up to 12 reagent sets (or up to 81 allergens)<\/li>\n<\/ul>\n<\/article>\n<article class=\"fullText dphclss0\">The Alisei Q.S. uses bare-coded reagents to ensure maximum control during testing, and a validated test routine from the assay. All bottles (reagents &#8211; standards &#8211; controls) are housed on chilled plates.<br>\nMultiple reagents on two separate racks can be loaded on the machine. The charging area is easily accessible for easy loading of reagents, samples and polymer tips through a transparent, large sliding window. The reagent and sample racks are easily removable with practical handles to quickly store the reagents in the refrigerator.<\/article>\n<section class=\"pageSec sw100 dphclss3\"><div class=\"dphclss4 fullText bw100\"><\/div><\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Double pipetting system<\/h3><\/div>\n<section class=\"pageSec sw100 \">\n<article class=\"twoThirdText dphclss0\">The pipetting system consists of two independent needles that are able to aspirate from two adjacent samples or from the same reagent and dispense into two separate wells simultaneously. Each needle is connected to two syringe pumps (2500 \u00b5L and 1000 \u00b5L) to dispense reagent or sample. To ensure the correct functioning of the system, each needle is equipped with a fluid and clot detection system.<\/article><div class=\"thirdSpalten dphclss0\"><div class=\"dphclss5 fullText\"><\/div>two independent needles<\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Barcode reader offers reliability<\/h3><\/div>\n<section class=\"pageSec sw100 \">\n<article class=\"twoThirdText dphclss0\">The sample identification allows true positive sample identification of samples (PSID) via an integrated barcode reader. This new feature results in the most reliable sample collection, sample identification and match test results and prevents user error.<\/article><div class=\"thirdSpalten dphclss0\"><div class=\"dphclss6 fullText\"><\/div>Barcode reader reads samples and reagents<\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Dosing and diluting<\/h3><\/div>\n<article class=\"fullText dphclss0\">The Alisei Q.S. has a high-precision robotic arm powered by stepper motors and controlled by optical and mechanical sensors. It is equipped with 2 dosing systems \/ needles, which make it possible to work independently of each other and to enable highly efficient pipetting.<br><br>\nPipettier speed serum: <strong>700 samples\/hour<\/strong><br>\nPipettier speed reagents: <strong>1500 Wells\/Hour<\/strong><br>\nLiquid level detection for optimal detection of fibrin clots and insufficient volume\n<\/article>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Incubate and mixing<\/h3><\/div>\n<article class=\"fullText dphclss0\">The microtiter plate carousel is designed to process 6 microtiter plates at the same time. Each microtiter plate can be edited and programmed completely individually. In addition, a single microtiter plate can be run.<br>\nThe microtiter plate carousel can perform linear shaking with a programmable intensity and period for each plate separately.<\/article>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">8-channel washing station<\/h3><\/div>\n<section class=\"pageSec sw100 \">\n<div class=\"twoThirdSpalten dphclss0\">\n<article class=\"fullText dphclss0\">The washing station has an 8-channel wash head with two parallel needles each, suitable for washing both &#8216;U&#8217; and flat bottom wells. Cycles, volume and number of washes can be easily programmed by the operator and three washing buffers + distilled water can be loaded on board at the same time.<\/article>\n<article class=\"fullText dphclss0\">\n<\/article>\n<article class=\"fullText\">\n<strong>Washing volume:<\/strong> programmable from 100 to 350 \u00b5l<br>\n<strong>Number of cycles:<\/strong> programmable from 1 to 9 cycles<br>\n<strong>Impact time:<\/strong> programmable from 1 second to 3 minutes<br>\n<strong>Pressure:<\/strong> programmable<br>\n<br>\nEach protocol can be programmed by the operator with multiple washes that differ in cycle, volume, holding time, and pressure.\n<\/article>\n<\/div>\n<div class=\"thirdSpalten dphclss0\">\n<div class=\"dphclss7 fullText radimPicMobFix\"><\/div>\nAlisei Q.S.: 8-channel washing station\n<\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Reading<\/h3><\/div>\n<section class=\"pageSec sw100 \">\n<div class=\"twoThirdSpalten dphclss0\">\n<article class=\"fullText\">\nThe reading station has an 8-channel photometer, which can be programmed by the operator for reading with a single, double or triple beam (vertical measurement). With a triple beam (over-range measurement), the instrument automatically converts the absorbance values measured at the different wavelengths. Measurements can be taken at one, two or more wavelengths.<br>\n<br>\n<strong>The normally provided filters:<\/strong> 405, 450, 492, 550 and 620 nm<br>\n<strong>Reader range:<\/strong> 0-3 OD in Bichromatism; 0-9 OD in polychromatism\n<\/article>\n<\/div>\n<div class=\"thirdSpalten dphclss0\">\n<div class=\"dphclss8 fullText radimPicMobFix\"><\/div>\nAlisei Q.S.: 8-channel photometer\n<\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Equipment maintenance<\/h3><\/div>\n<article class=\"fullText dphclss0\">\nThe Alisei Q.S. has been a sophisticated, reliable tool for everyday use for years to maximize the efficiency of your laboratory:<br>\nPreparation and follow-up of working time: 5 minutes per day<br>\nNo warm-up phase required.<br>\nSelf-diagnostic and alarm procedures are an essential part of the Alisei Q.S..<br>\n<\/article>\n<span class=\"dphclss9\">Simple maintenance procedures:<\/span>\n<section class=\"pageSec sw100 dphclss3\">\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">daily<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">Cleaning at the end of the run &#8211; fully automatic.<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">weekly<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">General cleaning of the workspace of liquids.<br>Empty all tanks to remove residual buffers. Rinse with DI water.<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">monthly<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">Wipe off the work area, plate trays, and waste bin.<br>Check tanks and visible hoses<\/div><\/div>\n<\/section>\n\n<div class=\"fullText radimHeadSpaceUp\"><h2 class=\"pageHead textLeft\">Smart software<\/h2><\/div>\n<article class=\"fullText\">\nIntelligent software control allows you to quickly, easily customize, monitor and manage all settings and data, as well as process and deliver results to your lab information system:\n<\/article>\n<section class=\"pageSec sw100 dphclss3\">\n<div class=\"twoThirdSpalten\">\n<ul>\n<li>Programming and changing test protocols<\/li>\n<li>Insert work lists with all relevant patient data<\/li>\n<li>Monitoring the entire test run<\/li>\n<li>View and manage the final results<\/li>\n<li>Personalizing and printing the patient report<\/li>\n<li>Standard curve retrieval function<\/li>\n<li>T. M. S. (Time Management System)<\/li>\n<li>Quality control functions<\/li>\n<li>Compatible with laboratory information systems<\/li>\n<\/ul>\n<\/div>\n<div class=\"thirdSpalten\">\n<div class=\"dphclss10 fullText\"><\/div>\n<\/div>\n<\/section>\n<article class=\"fullText dphclss11\">\n<div class=\"partslidersoftware\"><div class=\"partslidesoftware\" data-state=\"1\" data-rev=\"0\"><img decoding=\"async\" class=\"thirdTabelle\" src=\"https:\/\/www.radim.com\/wp-content\/uploads\/11_start.jpg\"><img decoding=\"async\" class=\"thirdTabelle\" src=\"https:\/\/www.radim.com\/wp-content\/uploads\/1_patient_data.jpg\"><img decoding=\"async\" class=\"thirdTabelle\" src=\"https:\/\/www.radim.com\/wp-content\/uploads\/2_allergens.jpg\"><img decoding=\"async\" class=\"thirdTabelle\" src=\"https:\/\/www.radim.com\/wp-content\/uploads\/3_allergens_summary.jpg\"><img decoding=\"async\" class=\"thirdTabelle\" src=\"https:\/\/www.radim.com\/wp-content\/uploads\/4_control_sera.jpg\"><img decoding=\"async\" class=\"thirdTabelle\" src=\"https:\/\/www.radim.com\/wp-content\/uploads\/5_calibrations.jpg\"><img decoding=\"async\" class=\"thirdTabelle\" src=\"https:\/\/www.radim.com\/wp-content\/uploads\/6_workplan.jpg\"><img decoding=\"async\" class=\"thirdTabelle\" src=\"https:\/\/www.radim.com\/wp-content\/uploads\/7_washing-solutions.jpg\"><img decoding=\"async\" class=\"thirdTabelle\" src=\"https:\/\/www.radim.com\/wp-content\/uploads\/8_samples.jpg\"><img decoding=\"async\" class=\"thirdTabelle\" src=\"https:\/\/www.radim.com\/wp-content\/uploads\/9_reagents.jpg\"><img decoding=\"async\" class=\"thirdTabelle\" src=\"https:\/\/www.radim.com\/wp-content\/uploads\/10_plates.jpg\"><img decoding=\"async\" class=\"thirdTabelle\" src=\"https:\/\/www.radim.com\/wp-content\/uploads\/11_start.jpg\"><img decoding=\"async\" class=\"thirdTabelle\" src=\"https:\/\/www.radim.com\/wp-content\/uploads\/1_patient_data.jpg\"><img decoding=\"async\" class=\"thirdTabelle\" src=\"https:\/\/www.radim.com\/wp-content\/uploads\/2_allergens.jpg\"><\/div><nav class=\"partslidernav\"><a class=\"partsliderPrev\" onclick=\"partslidebacksoftware();\"><span class=\"icon iconLeftArr\"><\/span><\/a><a class=\"partsliderNext\" onclick=\"partslidesoftware();\"><span class=\"icon iconRightArr\"><\/span><\/a><\/nav><\/div>\n<\/article>\n\n<div class=\"fullText radimHeadSpaceUp\"><h2 class=\"pageHead textLeft\">ELISA results manager<\/h2><\/div>\n<article class=\"fullText dphclss0\">\nThe software supports the processing of raw data from ELISA tests and their accurate conversion to the final concentration units. It allows evaluation of the test results using the most appropriate calculation models for the ELISA signal-concentration relationship.<br>\nLogistic curve-based parametric methods such as 4-parameter logistics (4PL) and Live Parameter Logistic (5PL) models have the closest correlation with real signal concentration dependence in ELISA assays.<br>\n<br>\nThe calculated results based on these methods have very little variability and high reproducibility. Therefore, they are considered <strong>the most suitable models for both competitive and &#8220;sandwich&#8221; ELISAs<\/strong> viewed. However, these calculation modes are not always available in the standard equipment software for demonstrating the ELISA test results. In this case, the ELISA Results Manager software provides an upgrade of the results analysis.\n<\/article>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Key program benefits:<\/h3><\/div>\n<article class=\"fullText dphclss0\">\n<ul>\n<li>Calculating results based on 4PL and 5PL models<\/li>\n<li>Visualization of the calibration curves<\/li>\n<li>Simplified information entry<\/li>\n<li>Processing the data received on an ELISA device<\/li>\n<li>Calculation of sample concentrations and statistics<\/li>\n<li>Printable results<\/li>\n<\/ul>\n<\/article>\n<section class=\"pageSec sw100 dphclss3\"><div class=\"dphclss12 fullText bw100 radimPicMobFix\"><\/div><\/section>\n\n<div class=\"fullText radimH\"><h2 class=\"pageHead textLeft\">Technical specifications Alisei Q.S.<\/h2><\/div>\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Dosing<\/h3><\/div>\n<section class=\"pageSec sw100 dphclss3\">\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">microtiter plates:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">6<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Parameter:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">max. 12 in one run<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Samples:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">max. 360 in one run<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Pipetting volume:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">7 \u00b5L &#8211; 1000 \u00b5L<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Precision tip 10 \u00b5L:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">less than 2.5%<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Tipp 100 \u00b5L:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">less than 1%<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Needle:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">less than 1.5%<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Throughput samples:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">700 \/ h (500 \u00b5L washing)<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Throughput reagents:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">1400 Wells \/ h<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Fill level sensor:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">Capazitive for needle<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Incubators:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">6<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Temperature:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">RT \/ RT +5 \u00b0C bis +45 \u00b0C<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Heating time:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">5 min<\/div><\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Washing<\/h3><\/div>\n<section class=\"pageSec sw100 dphclss3\">\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Buffer:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">4 with filler stander recognition<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Stations:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">1<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Liquid trap:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">10L with &#8220;Full&#8221; sensor<\/div><\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Photometer<\/h3><\/div>\n<section class=\"pageSec sw100 dphclss3\">\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Units:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">1<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Reading:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">from 0-3 OD (mono \/ dual \/ triple wavelength)<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Spectral range:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">400 &#8211; 700 nm<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Interference filters:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">5<\/div><\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Software<\/h3><\/div>\n<section class=\"pageSec sw100 dphclss3\">\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Operating system:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">Windows 10<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Interface:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">Bidirectional ASTM (LIS compatible)<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Internal quality control:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">Levey Jennings and Westguard rules<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Data reduction:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">Standard interpolations<\/div><\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Dimensions<\/h3><\/div>\n<section class=\"pageSec sw100 dphclss3\">\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Depth:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">73 cm<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Height:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">60 cm<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Width:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">140 cm<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Weight:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">100 kg<\/div><\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Electrical specifications<\/h3><\/div>\n<section class=\"pageSec sw100 dphclss3\">\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Voltage:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">110 or 220 V AC<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Frequency:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">50-60 Hz<\/div><\/div>\n<div class=\"tableRow\"><div class=\"radimTabelle forthTabelle\">Power:<\/div><div class=\"tableSep tableSepf\"><\/div><div class=\"radimTabelle threeForthTabelle\">800 VA<\/div><\/div>\n<\/section>\n\n<div class=\"fullText radimSubHead\"><h3 class=\"pageHead textLeft\">Compliance<\/h3><\/div>\n<article class=\"fullText dphclss0\">\nSafety CE certified\n<\/article>","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-4289","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.radim.com\/en\/wp-json\/wp\/v2\/pages\/4289","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.radim.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.radim.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.radim.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.radim.com\/en\/wp-json\/wp\/v2\/comments?post=4289"}],"version-history":[{"count":9,"href":"https:\/\/www.radim.com\/en\/wp-json\/wp\/v2\/pages\/4289\/revisions"}],"predecessor-version":[{"id":7539,"href":"https:\/\/www.radim.com\/en\/wp-json\/wp\/v2\/pages\/4289\/revisions\/7539"}],"wp:attachment":[{"href":"https:\/\/www.radim.com\/en\/wp-json\/wp\/v2\/media?parent=4289"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}